LSZH Mineral Insulated 750V Cable

Type: 111222

Voltage: 750V

Features:

Application:

Product introduction

Type Cu、Al Specifications Core NO. Voltage
111222 111222 11122 111222
補(bǔ)充說(shuō)明:

Type description exampl

Type exampl

For Example:

Product structure diagram

Product details

Examining report

Mineral Insulated Cables are used to provide circuit integrity for power and control circuits of critical equipment such as:

    1. ·Hospital operating rooms

    2. ·Air pressurisation system for stairwells

      ·Fire alarm systems

      ·Emergency power systems、Emergency lighting systems

      ·Sprinkler systems

    3. ·Public buildings e.g. theatres, cinemas, hotels, schools

  •  
    1. · Tunnels and mines

    2. · Temperature measurement devices; RTD's, thermocouples

      · Close to or inside industrial foundries, kilns

      · Hazardous areas where flammable gases may be present

    3. · Transport hubs - railway stations, airports etc

MI cable is the best choice for building fire safety line laying

BS 6387: Cable Fire Test

Fire Performance BS 6387 Performance Requirements for Cables Required to Maintain Circuit Integrity under Fire Conditions.This standard details the following tests to categorise cables according to their fire withstand capabilities.

  • Resistance to Fire

    The cable is tested by exposure to gas burner flames while passing a current at its rated voltage.

    Four survival categories are defined in the Performance Table below.

    • Symbol condition
    • A650°C for 3 hours
    • B750°C for 3 hours
    • C 950°C for 3 hours
    • D950°C for 20 minutes

  • Resistance to Fire with Water

    A new sample of cable is exposed to flames at 650°C for 15 minutes whilst passing a current at the rated voltage and then the spray is turned on to give exposure to both fire and water for a further 15 minutes.

    The grade results are as follows:

    • Symbolcondition
    • W650°C for 15 minutes

  • Resistance to Fire with Mechanical Shock

    The final requirement is mechanical shock damage. A fresh sample of cable is mounted on a backing panel in an S-bend and is exposed to flames whilst the backing panel is struck with a solid steel bar the same diameter as the cable under test every 30 seconds for 15 minutes.

    Whilst the cable has been exposed to temperatures as defined in the Performance Table below.

    • Symbolcondition
    • X650°C for 15 minutes
    • Y750°C for 15 minutes
    • Z950°C for 15 minutes

Beyond The Standard

Sunwin MI Cable can easily comply and withstand the most onerous categories of C, W and Z using one single Cable Sample

Product support

Related products

We carefully select, select good raw materials, to create high-quality wire and cable.
Give the user a rest assured.

广灵县| 延长县| 神木县| 渝北区| 泾源县| 定南县| 临泽县| 启东市| 衡南县| 镇坪县| 宜城市| 扎鲁特旗| 克拉玛依市| 陈巴尔虎旗| 巴塘县| 岳阳县| 冀州市| 武乡县| 惠州市|